요꼬가와는 1915년 창립이래 계측, 제어, 정보기술을 축으로
최첨단의 제품을 산업계에 제공함으로써 사회 발전에 공헌해오고 있습니다.
Batteries are characterized by their ability to deliver the required current over some period of time, called Amp-hours. Also known as capacity, different types of batteries have different characterizations curves that show their amp-hours as a function of time.
Lead Acid Battery Testing Methods
Verifying the manufacturer's capacity after the battery has been used for some time is known as a battery charge-discharge test.
How To Test Battery Capacity With Multimeter
Source measure units, devices that function both as a power supply and a multimeter/electronic load, are ideal for these types of tests. In this video, applications engineer Barry Bolling uses a GS610 source measure unit to perform a charge-discharge test on a lead acid battery to show how to test lead acid battery capacity.
l Related Industries l
Renewable Energy
1-Channel
±110V / ±0.5A or ±12V / ±3.2A
Resolution: 1 µV / 100 pA
Sweep: Linear, Log, Custom
Output: DC, Pulse (50 µs to 3600 s)
A Source Measurement Unit (SMU) is a flexible test instrument which is capable of both sourcing and measuring voltage and/or current at the same time.